Collars
The Promaseal CIH Cast-in Collar from Promat has been tested with a wide range of pipes, achieving a fire resistance of up to 240 minutes in accordance with AS 1530.4 and AS 4072.1. The product comes in three sizes and has been tested with a wide range of plastic pipes including uPVC, HDPE, PPR, Rehau, Wavin, Tri Plus, Pressure Pipe, dBlue, PE, PEX. Cast in fire collars are more economical on larger projects and allow for accurate set out of pipework, making it the preferred collar of choice for builders, plumbers, building certifiers and re-sellers due to the extensive range of approvals. PROMASEAL CIH cast-in fire collars are designed for plastic pipe penetrations. For other services such as electrical cables or lagged copper pipes, please view our other firestopping product selections.
The PROMASEAL CIL Low Cast In Collar is designed to be fixed to formwork prior to the pouring of concrete floor slabs. The collar accommodates the uPVC pipe fitting within the thickness of the slab enabling space saving. Promat’s range of cast in fire collars allow for accurate set out of pipe work, and are more cost effective than retrofit collars where a large number are required. There are different types of fire collars for different applications. The PROMASEAL CIL Low Cast In Collar is primarily for uPVC plastic pipe penetrations however Promat manufactures a range of fire collars that are tested for all types of building services including; plastic pipes, electrical cables, lagged copper pipes, copper pair coils and other general building services. It is not suitable to protect floor waste penetrations. For protecting floor waste penetrations please refer to our floorwaste collar selection.
The PROMASEAL Fire Resistant Services Seal Collar is designed to be fixed to the formwork prior to pouring concrete floor slabs and to provide openings in floor slabs for various combustible service penetrations. This Collar is available in one size only and accommodates multiple or single services. This product has multiple approvals including electrical cables, lagged plastic pipes, copper pair coils, lagged copper pipes and multiple PVC pipes. After installation of the services, the collar is back filled with PROMASEAL Mortar.
Trafalgar’s FyreCOLLAR Cast-in High Top range can achieve up to 4 hours protection across a huge range of common pipes, types and sizes. These collars are designed for use in concrete floor slabs up to 250mm thick, where the head of the high cast-in fire collar extends above the surface of the floor so that sections of pipe are not needed as part of the installation process. Once the concrete is set, simply run your plastic or metal pipes through the collars which are fitted with a rubber gasket to prevent smoke leakage through the penetration. Approved with PVC, HDPE, PP-R, PP, RAUPIANO and copper and steel pipes up to 100mm diameter. The FyreCOLLAR Cast-In High range is also fire tested for up to 2 x pair coil bundles with FR insulation and associated cables. The high-top cast-in fire collar is available in three size and suits pipes 40mm up to 100mm.
Trafalgar’s FyreCOLLAR Cast-in Low Top range can achieve up to 4 hours protection across a huge range of common pipes, types and sizes. Specifically for stack and plumbing pipes, the low top cast-in fire collars are suitable for all slab thicknesses. These low-profile collars are cast in place with a section of pipe installed before the concrete is poured, for pipework to be connected to once set. The collar is designed to accommodate a numerous range of 40mm to 100mm plastic pipes including PVC, HDPE, PP-R, PP, RAUPIANO and even insulated pair coil bundles. Stack and floor waste testing covers a wide range of pipes with fire elbows, S-bends and 4-way risers.
With the price of copper increasing, alternative pipe materials are becoming more and more common for plumbing systems. This presents an issue where new services are being introduced to the market with limited passive fire protection systems tested to maintain the FRL of the fire barriers that they penetrate through. One such example is larger diameter (40, 50, and 63mm) Multi-Layer Pipes like PEX-AL-PEX which are becoming more common in plumbing installations. Conventional intumescent-only fire collars are not adequate to close larger diameters of PEX-Al-PEX pipe. Trafalgar has developed a mechanically assisted intumescent fire collar system to address this problem, fire tested specifically for PEX-Al-PEX pipe materials and achieving FRL ratings of up to -/120/120 in concrete floor slabs.
PROMASEAL CFC Conduit Collars are available in one size (32mm) and can be used on pipes ranging from 16mm to 32mm in diameter without any modification requirements for smaller sizes. Approved with a large variety of pipes including PEX, uPVC, PB, PEX/Al/PEX, Cables, Conduits and many others. Insulation criteria will vary depending on the service and substrate type however the collar is tested in a wide variety of wall types including fire rated plasterboard, Speedpanel & AAC/Hebel amongst others. The conduit collar has been tested to Australian Standards and has achieved a fire resistance level of up to 4 hours, when tested to AS 1530: Part 4 and AS 4072: Part 1.
Trafalgar Conduit Fire Collars are designed to provide maximum protection against the spread of fire through walls and floors that are penetrated by plastic conduits and plastic pipes. FyreCOLLARs are simple to install, simply retrofit around the service and fix to the wall or floor. Suitable for a range of plastic pipes and mixed services including Data NBN Conduits, Electrical Conduits, PVC pipes, PEX pipes, and PEX-AL-PEX pipes. Fire collar sizes range from 25mm and up to 100mm to cover multiple service sizes, and are fire tested in a range of wall and floor systems with a wide variety of service types.
Available in both retrofit and cast-in options, the PROMASEAL Floorwaste Collar by Promat is designed to provide fire resistance where floor wastes penetrate wet areas. The collars have been tested for cast-in floor applications to AS1530: Part 4 and AS4072: Part 1, which achieved an FRL of -/120/120 for 50 & 100mm uPVC and -/180/180 for 80mm uPVC. 100mm HDPE and 100mm Rehau Raupiano pipe are also approved with Promat’s floorwaste collar. Minimum slab depth must be 150mm.
Trafalgar’s BladeRUNNER is ideal for confined spaces and its compact design makes it a functional choice for narrow or restricted areas. Whether you’re dealing with limited clearance around pipe penetrations or if the pipe elbow is too close to the slab, the BladeRUNNER provides an effective fire safety solution without the need for space alterations and board construction. The BladeRUNNER is a slimline spring-loaded fire collar that can be easily installed around existing floor waste or drain/waste/vent pipe penetrations, providing a cost-effective alternative to expensive fire board enclosures or bulky retrofit collars. BladeRUNNER is tested to AS1530.4 and is suitable for 40-100mm PVC pipes to upgrade incorrect or non-existent fire collars. The slimline design is also perfect for drain/waste/vent applications (AKA stack pipes) where there is no room for a traditional bulky retro-fit fire collar and is tested for PVC pipe materials connected to P-traps or elbows directly underneath the slab.
Floor waste applications are not continuous pipes, often having a metal grille finished at the floor level above. Standard intumescent collars will not close off the penetration quickly enough to prevent early fire spread. Trafalgar’s floor waste fire collar is fitted with a spring-loaded mechanical system that will shut the plastic pipe early when exposed to fire conditions, to effectively close off the penetration whilst the intumescent material swells to close off any remaining gaps, stopping the spread of fire in this unique application. Tested to AS1530.4 – 2014, the floor waste FyreCOLLAR is available in both high and low top options and has been tested for a range of pipe materials connected to 4-way risers and P-traps directly underneath the slab for the following 100mm PVC, HDPE, Raupiano, and DBlue pipes:
BOSS MaxiCollars provide a high-performance fire protection solution and are a good choice for tight fitting areas or closely installed pipes. BOSS MaxiCollars have extensive fire test approvals including AS1530.4: 2014 & AS4072.1 offering 60min, 90min, 120min & 240min FRL’s. Tested in a wide variety of walls, floors and ceilings, MaxiCollars have approvals in the following substrates:
- FR Plasterboard
- Concrete & Masonry walls
- BOSS Batt
- AAC / Hebel
- Speedpanel
- Supapanel
- Pronto Panel
- Comflor floor slabs
- Cross Laminated Timber
Firefly RF Fire Collars are used to close off PVC pipes, HDPE pipes, beer lines, air conditioner lagged pipes and cables where they penetrate Firefly Intubatt Systems in both vertical and horizontal applications. Firefly retrofit fire collars are made from steel and high pressure graphite Intumescent, allowing for fire resistance levels of up to -/120/120. Tested to AS1530.4-2014 and assessed in accordance with AS4072.1-2005.
The square based PROMASEAL®-FC Retrofit Collar is a multipurpose collar designed for use with concrete slabs, masonry and lightweight walls and lined ceilings. The collar can be retrofitted where necessary making for easy installation and fire upgrades. Approved for retrofitting around services including uPVC, HDPE, Raupiano, GF Cool Fit 2.0, Fastflow, Post Mix Lines, Geberit Super Tube, Triplus, cables, and lagged copper pipes. Tested and assessed in accordance with AS 1530.4 – 2014 to achieve up to 4 hrs fire resistance. Horizontal and vertical systems available for a variety of wall, floor, and ceiling applications such as plasterboard, Speedpanel, AAC, Hebel, and concrete)
Circular based PROMASEAL® Retrofit Collar (FCS type) is designed to be fitted around uPVC pipes through floor slabs up to 100mm in diameter. The larger opening within the collars will accommodate uPVC pipe fittings and can be installed over uPVC sockets/joiners. Tested with uPVC as well as Postmix and beer lines. Also suitable for protecting wall penetrations for Raupiano plastic pipes, cables, and insulated copper pipes.
FyreSHEATH is a system designed to simplify the use of FyrePEX High-Performance Fire Mastic, ensuring a compliant penetration seal everytime to achieve the required Fire Resistance Level of up to -/120/120. With FyreSHEATH, the hole size is no longer critical as it sets the annular gaps and fill depths automatically, making for easier certification as the sealant depth is easily visible. Suitable for concrete or masonry, Pronto Panel, WALSC, or single- and double-layer plasterboard walls. Tested to AS1530.4-2014 and compliant with AS4072.1.
Trafalgar offers a Premium range of retrofit fire collars that are designed to provide maximum protection against the spread of fire through walls and floors that are penetrated by plastic conduits, plastic pipes or air-conditioning service bundles. The retrofit collar range is fire tested in a variety of wall and floor systems on a wide selection of plastic pipes and mixed services including electrical conduits, HDPE and PVC pipes, HVAC bundles and insulated pipes and cables. The Trafalgar Retrofit FyreCOLLAR is available in multiple sizes ranging from 25mm to 150mm.
The intumescent PROMASTOP UniCollar® is a retrofit collar designed to maintain the integrity of fire-resistant elements for approved pipe services of any size. It is suitable for installation in various ceiling, floor, and wall penetrations. PROMASTOP UniCollar is tested with many new and existing types of plastic pipes using uPVC as a benchmark. The UniCollar is a single box solution approved for multiple pipe sizes and types including uPVC, HDPE, Raupiano, d-Blue, Triplus and many others. Also suitable to protect cable bunches and insulated metal pipes.
The Trafalgar Unicorn Continuous Fire Collar is the longest continuous collar supplied in the market and stands out as one of the only collars to receive approvals for PEX-A, PEX-B, and PEX-AL-PEX pipes without the necessity for wrap. However, the Unicorn fire collar has been fire tested and approved for multiple service applications including PVC, HDPE, and PEX, electrical conduits, data and communication cables, power cables, pair coil bundles, refrigeration lines and mixed service bundles. Used in conjunction with FyrePEX HP intumescent sealant, the collar expands quickly to seal around plastic pipes when a fire breaks out. Rigorously tested to meet AS 1530.4: 2014 standards and with Fire Resistance Levels (FRL) up to -/240/240, it guarantees compliance with the strictest safety codes. Fire testing and assessments are currently being expedited for approval with Trafalgar Maxilite bulkheads, to provide even more fire safety solutions.
PROMASEAL® Wall Collar is designed for insertion into fire resistant wall elements such plasterboard, concrete, and masonry and has been tested on uPVC and HDPE pipes allowing two-way protection using a single collar. Tested for uPVC, HDPE and other pipe types from 40 to 150mm diameter in fire rated plasterboard, shaft and vent walls, Hebel/AAC & Speedpanel. Allows for collars to be fit to the pipe before construction of the fire rated wall, saving significant time and avoiding coordination issues between trades.
Retrofit fire collars, made from steel and high-pressure graphite intumescent. Used to fire stop a variety of services which penetrate the numerous fire-resistant substrates.
PROMASEAL® CIH Collar is designed to be fixed to formwork prior to the pouring of concrete floor slabs. It has been tested with various uPVC and HDPE pipes.
PROMASTOP® UniCollar® is an intumescent device designed to maintain the integrity of the fire-resistant elements through which various plastic pipes pass. It is suitable for retrofit installation in various floors and walls like that in which it has been tested. In the event of a fire, the intumescent material in the PROMASTOP® UniCollar® rapidly expands, closing off the plastic pipe or combustible insulation and forming an insulating barrier.
Trafalgar FyreCOLLAR Conduit Fire Collars are designed to provide maximum protection against the spread of fire through walls and floors that are penetrated by plastic conduits and plastic pipes. FyreCOLLAR’s are simple to install, simply retrofit around the service and fix to the wall or floor.
PROMASEAL® Wall Collar is designed for insertion into fire resistant wall elements such plasterboard, concrete, masonry and has been tested on uPVC and HDPE pipes.
Trafalgar’s Australian Made Cast-In Floor Waste fire collars provide a full range of cast-in fire-stopping solutions for floor waste applications, with approvals up to 4 hours across a huge range of common pipe types and sizes.
Ideal for Space-Constrained Applications, its compact design makes it a functional choice for narrow or restricted areas. Whether you are dealing with limited clearance around pipe penetrations or if the pipe elbow is too close to the slab, the Bladerunner provides an effective fire safety solution without the need for space alterations and board construction.
FyreSHEATH is a system designed to simplify the use of FyrePEX™ High-Performance Fire Mastic, ensuring a compliant penetration seal everytime to achieve the FRL required up to a -/120/120, while minimising sealant waste from overfilling into the wall cavity and saving you money.